{"id":401,"date":"2019-06-18T08:43:52","date_gmt":"2019-06-18T08:43:52","guid":{"rendered":"https:\/\/teachingindustry.undip.ac.id\/?p=401"},"modified":"2019-06-18T08:43:54","modified_gmt":"2019-06-18T08:43:54","slug":"ddbd-ozone-plasma-reactor-generation-the-proper-dose-for-medical-applications","status":"publish","type":"post","link":"https:\/\/teachingindustry.undip.ac.id\/index.php\/2019\/06\/18\/ddbd-ozone-plasma-reactor-generation-the-proper-dose-for-medical-applications\/","title":{"rendered":"DDBD ozone plasma reactor generation: the proper dose for medical applications"},"content":{"rendered":"\n<p>M Azam<sup>1<\/sup>,&nbsp;M Restiwijaya<sup>2<\/sup>,&nbsp;A Z Zain<sup>1,2<\/sup>,&nbsp;S. Sumariyah<sup>1,2<\/sup>,&nbsp;E Setiawati<sup>1<\/sup>,&nbsp;V Richardina<sup>1<\/sup>,&nbsp;A R Hendrini<sup>3<\/sup>,&nbsp;B Dayana<sup>3<\/sup>,&nbsp;A W Kinandana<sup>2<\/sup>,&nbsp;F Arianto<sup>1,2<\/sup>,&nbsp;K N Bintang<sup>1<\/sup>,&nbsp;Y Putri<sup>1<\/sup>,&nbsp;Y K Valas<sup>1<\/sup>&nbsp;and&nbsp;M Nur<sup>1,2<\/sup><\/p>\n\n\n\n<p><sup>1<\/sup>Physics Department, Faculty of Science and Mathematics, Diponegoro University, Semarang<br><sup>2<\/sup>Center for Plasma Research, Faculty of Science and Mathematics, Diponegoro University, Semarang<br><sup>3<\/sup>Medical Faculty of Diponegoro University, Semarang, Indonesia<\/p>\n\n\n\n<p>Corresponding author: azam@fisika.undip.ac.id<\/p>\n\n\n\n<p>Abstract<\/p>\n\n\n\n<p style=\"text-align: justify;\">Double Dielectric Barrier Discharge (DDBD) ozone plasma reactor generation are presented in this paper. The generation of this reactor generates ozone concentration which can be arranged upon the proper dose for medical applications. AC high voltage is applied to the range of 0-3 kV and the frequency of 50 Hz. Pure oxygen gas was piped into the DDBD reactor with flow rate variations of 2, 4 and 6 L\/min. The results showed that current as a function of voltage where the current is increased with the increasing of voltage. Ozone productivity is shown by the significant increase of current. Ozone concentration is increasing as the increase of the voltage provided, but rather the concentration of ozone is decreasing as the increasing of flow rate. The Ozone capacity is affected by ozone concentration and flow rate, and can be used to determine the ozone dose. The proper dose of ozone can be ozone therapy for various kinds of diseases.<\/p>\n\n\n\n<p>Read more at: <a href=\"https:\/\/iopscience.iop.org\/article\/10.1088\/1742-6596\/1217\/1\/012026\">https:\/\/iopscience.iop.org\/article\/10.1088\/1742-6596\/1217\/1\/012026<\/a><\/p>\n\n\n\n<div class=\"wp-block-file\"><a href=\"https:\/\/teachingindustry.undip.ac.id\/wp-content\/uploads\/2019\/06\/Azam_2019_J._Phys.__Conf._Ser._1217_012026.pdf\">Download file:<\/a><a href=\"https:\/\/teachingindustry.undip.ac.id\/wp-content\/uploads\/2019\/06\/Azam_2019_J._Phys.__Conf._Ser._1217_012026.pdf\" class=\"wp-block-file__button\" download>Download<\/a><\/div>\n","protected":false},"excerpt":{"rendered":"<p>M Azam1,&nbsp;M Restiwijaya2,&nbsp;A Z Zain1,2,&nbsp;S. Sumariyah1,2,&nbsp;E Setiawati1,&nbsp;V Richardina1,&nbsp;A R Hendrini3,&nbsp;B Dayana3,&nbsp;A W Kinandana2,&nbsp;F Arianto1,2,&nbsp;K N Bintang1,&nbsp;Y Putri1,&nbsp;Y K Valas1&nbsp;and&nbsp;M Nur1,2 1Physics Department, Faculty of Science and Mathematics, Diponegoro University, Semarang2Center for Plasma Research, Faculty of Science and Mathematics, Diponegoro University, Semarang3Medical Faculty of Diponegoro University, Semarang, Indonesia Corresponding author: azam@fisika.undip.ac.id Abstract Double Dielectric Barrier Discharge [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[7],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v15.7 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>DDBD ozone plasma reactor generation: the proper dose for medical applications - Teaching Industry Universitas Diponegoro<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/teachingindustry.undip.ac.id\/index.php\/2019\/06\/18\/ddbd-ozone-plasma-reactor-generation-the-proper-dose-for-medical-applications\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"DDBD ozone plasma reactor generation: the proper dose for medical applications - Teaching Industry Universitas Diponegoro\" \/>\n<meta property=\"og:description\" content=\"M Azam1,&nbsp;M Restiwijaya2,&nbsp;A Z Zain1,2,&nbsp;S. Sumariyah1,2,&nbsp;E Setiawati1,&nbsp;V Richardina1,&nbsp;A R Hendrini3,&nbsp;B Dayana3,&nbsp;A W Kinandana2,&nbsp;F Arianto1,2,&nbsp;K N Bintang1,&nbsp;Y Putri1,&nbsp;Y K Valas1&nbsp;and&nbsp;M Nur1,2 1Physics Department, Faculty of Science and Mathematics, Diponegoro University, Semarang2Center for Plasma Research, Faculty of Science and Mathematics, Diponegoro University, Semarang3Medical Faculty of Diponegoro University, Semarang, Indonesia Corresponding author: azam@fisika.undip.ac.id Abstract Double Dielectric Barrier Discharge [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/teachingindustry.undip.ac.id\/index.php\/2019\/06\/18\/ddbd-ozone-plasma-reactor-generation-the-proper-dose-for-medical-applications\/\" \/>\n<meta property=\"og:site_name\" content=\"Teaching Industry Universitas Diponegoro\" \/>\n<meta property=\"article:published_time\" content=\"2019-06-18T08:43:52+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2019-06-18T08:43:54+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\">\n\t<meta name=\"twitter:data1\" content=\"1 minute\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/teachingindustry.undip.ac.id\/#website\",\"url\":\"https:\/\/teachingindustry.undip.ac.id\/\",\"name\":\"Teaching Industry Universitas Diponegoro\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/teachingindustry.undip.ac.id\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/teachingindustry.undip.ac.id\/index.php\/2019\/06\/18\/ddbd-ozone-plasma-reactor-generation-the-proper-dose-for-medical-applications\/#webpage\",\"url\":\"https:\/\/teachingindustry.undip.ac.id\/index.php\/2019\/06\/18\/ddbd-ozone-plasma-reactor-generation-the-proper-dose-for-medical-applications\/\",\"name\":\"DDBD ozone plasma reactor generation: the proper dose for medical applications - Teaching Industry Universitas Diponegoro\",\"isPartOf\":{\"@id\":\"https:\/\/teachingindustry.undip.ac.id\/#website\"},\"datePublished\":\"2019-06-18T08:43:52+00:00\",\"dateModified\":\"2019-06-18T08:43:54+00:00\",\"author\":{\"@id\":\"https:\/\/teachingindustry.undip.ac.id\/#\/schema\/person\/9d9b6d81bf44cf2f1adfd2684dd19ae1\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/teachingindustry.undip.ac.id\/index.php\/2019\/06\/18\/ddbd-ozone-plasma-reactor-generation-the-proper-dose-for-medical-applications\/\"]}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/teachingindustry.undip.ac.id\/#\/schema\/person\/9d9b6d81bf44cf2f1adfd2684dd19ae1\",\"name\":\"Andi Kinandana\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/teachingindustry.undip.ac.id\/#personlogo\",\"inLanguage\":\"en-US\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/037beaa80c2074aa149556291ac88675?s=96&d=mm&r=g\",\"caption\":\"Andi Kinandana\"},\"sameAs\":[\"http:\/\/cpr.undip.ac.id\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","_links":{"self":[{"href":"https:\/\/teachingindustry.undip.ac.id\/index.php\/wp-json\/wp\/v2\/posts\/401"}],"collection":[{"href":"https:\/\/teachingindustry.undip.ac.id\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/teachingindustry.undip.ac.id\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/teachingindustry.undip.ac.id\/index.php\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/teachingindustry.undip.ac.id\/index.php\/wp-json\/wp\/v2\/comments?post=401"}],"version-history":[{"count":1,"href":"https:\/\/teachingindustry.undip.ac.id\/index.php\/wp-json\/wp\/v2\/posts\/401\/revisions"}],"predecessor-version":[{"id":403,"href":"https:\/\/teachingindustry.undip.ac.id\/index.php\/wp-json\/wp\/v2\/posts\/401\/revisions\/403"}],"wp:attachment":[{"href":"https:\/\/teachingindustry.undip.ac.id\/index.php\/wp-json\/wp\/v2\/media?parent=401"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/teachingindustry.undip.ac.id\/index.php\/wp-json\/wp\/v2\/categories?post=401"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/teachingindustry.undip.ac.id\/index.php\/wp-json\/wp\/v2\/tags?post=401"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}